Material Classification UL94-5V for 500W Vertical Burning Test

2015-08-13

Material Classification UL94-5V for 500W Vertical Burning Test

According to requirement of UL94, a material shall be classified UL94-5V as described as below:


 Criteria   5VA   5VB 
 Afterflame time plug afterglow time after fifth flame application for each individual bar specimen   ≤60s   ≤60s 
 Cotton Indicator ignited by flaming particles or drop from any specimen   No   No 
 Afterflame time plug afterglow time for each individual specimen after second flame application (t2+t3)  ≤30s   ≤60s 
 Burn-through (hole) of any plaque specimen   No   Yes 


Materials classified 5VA or 5VB shall also comply with the requirements described for materials classified V-0 or V-1


Horizontal Vertical Flame Test Equipment manufactured by Zhilitong Electromechanical Co., Ltd complies with UL94 classed 94-5VA and 94-5VB testing.

Previous : The Flame Gauge used for Horizontal Vertical Burner UL94

Next : How to determine UL94 classed V-1 testing ?

#

# # # # # # #

#